     Ultrafast System
monochromator; selected photon counting PMT; electronics; Windows based Lumex 3.1 software; installation, test measurements and personnel training.
FOG100
Fluorescence Up-Conversion System

Sum frequency generation (up-conversion) is used in the femtosecond optically gated (FOG) fluorescence kinetic measurement system FOG100 to achieve a temporal resolution of better than 100 femtoseconds. FOG100 is the first complete measurement system for femtosecond and picosecond lifetime and kinetic spectroscopy. It has been designed to be matched with any type of femtosecond oscillator or oscillator - amplifier system operating at > 1 KHz pulse repetition rate. The FOG100 includes optical unit together with 2-ns optical delay line; single or double
Detection of laser induced fluorescence with < 100 fs temporal resolution.
Covers fluorescence phenomena from femtoseconds to 2 ns.
Fluorescence kinetic measurements in solutions, vapours, thin films and solid samples.
Recommended laser pulse repetition rate: 1 KHz - 100 MHz
Standard configuration designed for femtosecond Ti:sapphire oscillator. Second harmonic generator is included.
Option wavelength conversion unit for third harmonic generation
Anisotropy kinetic measurements.
ExciPro-D
The ExciPro-D system is used in femtosecond or picosecond pump-probe absorption spectroscopy for transient absorbance (optical density) changes measurements. Two photodiode arrays are placed after an imaging spectrometer to measure probe and reference spectra, originating from femtosecond white light (continuum) generator. Photoinduced optical density changes are calculated from probe and reference spectra measured before and after the sample excitation.
The ExciPro-D system configuration:

Imaging spectrometer
Multi-channel detector head, containing two photodiode arrays and adapted to the spectrometer
2-ns optical delay line
Control unit, connected to a computer via serial port
Photodiode for the system synchronization and pump power measurements
Mechanical shutter (for 100 Hz - 10 Hz pulse repetition rate)
Mechanical chopper (for 1 kHz - 100 Hz pulse repetition rate)
ExciPro 1.02 software
Photodiode array and readout specifications:
Detector type: linear photodiode array
Number of pixels: 1024
Pixel pitch: 25 mm
Pixel height: 2.5 mm
Spectral response range (10% of peak): 200 - 1000 nm
Typical operation temperature: 25oC
14 bit ADC
Dynamic range: 5000
Pulse repetition rate: up to 1 kHz
Sensitivity (at the maximum of photodiode array spectral sensitivity): 2 x 104 photons / (pixel x count)
The ExciPro-D gives 10-5 DOD (rms) optical density changes sensitivity, measured as a base line noise when photodiode arrays are illuminated with continuous wave incoherent (lamp) light.
MPA50
Femtosecond Multipass Ti:Sapphire Amplifier

MPA50 Ti:sapphire amplifier system is based on the two-mirror confocal multipass Ti:sapphire amplifier configuration designed by CDP Corp. for effective femtosecond pulse amplification in different active media. MPA50 is a complete amplifier system containing pulse stretcher, multipass amplifier, pulse compressor, pulse picker and synchronisation electronics.
Two-mirror confocal design
8-pass configuration
Amplification of 30-fs pulses
Single-shot autocorrelator (option)
Harmonic generators (option)
Nd:YAG pump laser is required
TISSA20 seed laser is recommended
Specifications:
Output pulse width: < 50 fs for TISSA20 seed pulses
Operation wavelength: 780 - 840 nm
Pulse repetition rate: 10 - 50 Hz, 1 kHz
Output pulse energy: 1.0 mJ at 10 - 50 Hz, 0.3 mJ at 1 kHz
Output polarization: horizontal
Lotis LS series of frequency doubled Nd:YAG laser is recommended for the amplifier pumping at 10 - 50 Hz.
Please, contact us about recommended pump laser for 1 kHz operation.